
Counterflow Enduit Draft Fèmen Refwadisman Tower
Sa a kalite gwo kay won refwadisman opere lè li tire dlo cho nan pwosesis endistriyèl, sikile li nan echanjeur chalè, ak Lè sa a, lage li tounen nan pwosesis endistriyèl la apre li te refwadi.
- Livrezon rapid
- Asirans Kalite
- Sèvis Kliyan 24/7
Pwodwi Entwodiksyon
PwodwiDeskripsyon
KBL seri counterflow pwovoke bouyon fèmen refwadisman gwo kay won se yon sistèm refwadisman avanse yo itilize nan divès kalite anviwònman endistriyèl ak komèsyal yo. Sa a kalite gwo kay won refwadisman opere lè li tire dlo cho nan pwosesis endistriyèl, sikile li nan echanjeur chalè, ak Lè sa a, lage li tounen nan pwosesis endistriyèl la apre li te refwadi. Sa a reyalize atravè yon seri tib counterflow ak yon fanatik bouyon pwovoke ki trase lè nan gwo kay won an, refwadisman dlo pwosesis la. Sa a kalite gwo kay won refwadisman mande pou itilizasyon dlo minim epi li ka sove yon kantite siyifikatif enèji konpare ak sistèm refwadisman tradisyonèl yo louvri. Anplis de sa, paske li se yon sistèm fèmen, li pi an sekirite pou anviwònman an epi redwi potansyèl pou kontaminasyon oswa polisyon.

Karakteristik& Benefis
* Pa gen kontaminasyon nan sikwi prensipal la: Anpil pwosesis sivil ak endistriyèl mande pou kenbe likid pwosesis la gratis nan kontaminasyon nan anviwònman an ekstèn: sa a se ka a, pou egzanp, ak pifò pwosesis pwodiksyon manje. Gwo fò won refwadisman sikwi fèmen satisfè bezwen sa a: nan pratik, bobin yo separe likid pwosesis la ak lè anbyen aspire pa fanatik la, kenbe li pwòp epi gratis nan kontaminasyon nan yon bouk fèmen.
* Rediksyon nan Risk konjelasyon: Depi dlo pwosesis la sikile nan bobin echanj chalè a epi pa janm vin an kontak ak lè a, glycol ka ajoute nan li pou bese pwen konjelasyon likid la. Sa a se yon gwo avantaj espesyalman nan peyi frèt kote tanperati souvan desann anba zewo degre.
* Layout plant pi fasil
* Anprint redwi
* Pi wo efikasite tèmik
TeknikParamèt
|
Modèl |
Kapasite refwadisman (Kcal/h) |
Koule travay (m³/h) |
Dimansyon (L * W * H) (mm) |
Inlet ak Outlet Dyamèt |
|
KBL-05 |
150000 |
30 |
2800x1870x2450 |
DN80 |
|
KBL-06 |
180000 |
36 |
2800x1870x2450 |
DN80 |
|
KBL-07 |
225000 |
45 |
3400x1970x2600 |
DN100 |
|
KBL-08 |
260000 |
52 |
3400x1970x2600 |
DN100 |
|
KBL-09 |
300000 |
60 |
3400x1970x2600 |
DN100 |
|
KBL-10 |
350000 |
70 |
3400x1970x3250 |
DN125 |
|
KBL-12 |
400000 |
80 |
3400x1970x3250 |
DN125 |
|
KBL-13 |
450000 |
90 |
3400x1970x3250 |
DN125 |
|
KBL-14 |
500000 |
100 |
3400x2340x3250 |
DN125 |
|
KBL-15 |
550000 |
110 |
3400x2340x3250 |
DN125 |
|
KBL-16 |
600000 |
120 |
4200x2340x3350 |
DN150 |
|
KBL-17 |
650000 |
130 |
4200x2340x3350 |
DN150 |
|
KBL-18 |
700000 |
140 |
4200x2340x3350 |
DN150 |
|
KBL-19 |
750000 |
150 |
4200x2340x3350 |
DN150 |
|
KBL-20 |
800000 |
160 |
4800x2340x4200 |
DN200 |
|
KBL-21 |
900000 |
180 |
4800x2340x4200 |
DN200 |
|
KBL-22 |
1000000 |
200 |
4800x2340x4200 |
DN200 |
|
KBL-23 |
1100000 |
220 |
4800x2340x4200 |
DN200 |
|
KBL-24 |
1200000 |
240 |
5350x2340x4300 |
DN200 |
|
KBL-25 |
1300000 |
260 |
5350x2340x4300 |
DN200 |
|
KBL-26 |
1400000 |
280 |
6100x2340x4250 |
DN250 |
|
KBL-27 |
1500000 |
300 |
6100x2340x4250 |
DN250 |
|
KBL-28 |
1700000 |
340 |
5350x3200x4650 |
DN250 |
|
KBL-30 |
1900000 |
380 |
5350x3200x4650 |
DN250 |
|
KBL-32 |
2100000 |
420 |
5800x3200x4650 |
DN250 |
|
KBL-34 |
2500000 |
500 |
6500x3200x4700 |
DN300 |
|
KBL-36 |
2800000 |
560 |
6500x3200x4700 |
DN300 |
Remak: Paramèt teknik ki anwo yo se pou referans sèlman: paske pwodwi yo toujou ap mete ajou ak optimize, paramèt yo sijè a chanje san avètisman alavans.
AplikasyonArea


Baj popilè: counterflow pwovoke bouyon fèmen refwadisman gwo kay won, Lachin counterflow pwovoke bouyon fèmen refwadisman gwo kay won manifaktirè, Swèd, faktori







